{"product_id":"icp-hot-surface-igniter-for-rgs091sfba0aaaa-silicon-nitride-kit-ships-today","title":"ICP Hot Surface Igniter for RGS091SFBA0AAAA — Silicon Nitride Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM hot surface igniter (HSI) for the ICP \/ Heil \/ Tempstar \u003cstrong\u003eRGS091SFBA0AAAA\u003c\/strong\u003e gas furnace, supplied as OEM part number \u003cstrong\u003e1171306\u003c\/strong\u003e and bundled with the matching igniter wiring kit, OEM part \u003cstrong\u003e1188370\u003c\/strong\u003e. The igniter is the ignition source for the main burners: on a call for heat, the furnace control board energizes the igniter, it glows white-hot, and the gas valve opens so the burners light. Because the element runs through repeated heat-up\/cool-down cycles, it is one of the most common no-heat failure points on this furnace. Typical failure symptoms include a furnace that runs the inducer and blower but never lights, a cracked or visibly broken ceramic element, no glow during the ignition sequence, or a unit that locks out after three failed ignition attempts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171306 (igniter), 1188370 (wiring kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS091SFBA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis igniter and wiring kit are a factory-direct fit for the ICP\/Heil\/Tempstar\/Comfortmaker RGS091SFBA0AAAA furnace. The same OEM part is shared across many ICP-built single- and two-stage gas furnaces of this vintage. Always confirm your unit's model and serial tag before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect electrical power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter mounting and wire routing before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter without touching the ceramic. Handle the new element by the bracket only — skin oils shorten igniter life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter at the correct depth over the burner, install the wiring kit, and reconnect per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace inducer and blower run but the burners never ignite.\u003c\/li\u003e\n\u003cli\u003eCracked, chipped, or broken ceramic element.\u003c\/li\u003e\n\u003cli\u003eNo visible glow during the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after three failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027671236979,"sku":"1171306","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047624098163,"sku":"1171306-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-nitride-1171306_5f267d7a-504f-4b97-be9e-7541a0111896.jpg?v=1782892046","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgs091sfba0aaaa-silicon-nitride-kit-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}