{"product_id":"icp-hot-surface-igniter-for-rgs091leca0aaa-includes-wiring-kit-ships-today","title":"ICP Hot Surface Igniter for RGS091LECA0AAA — Includes Wiring Kit | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM hot surface igniter assembly (igniter #1171306 plus wiring harness kit #1188370) ignites the burners on the ICP \/ Tempstar \/ Heil RGS091LECA0AAA gas furnace. When the control board calls for heat, 120V is applied to the igniter element, which glows red-hot and lights the gas as it leaves the burners. Hot surface igniters are a wear item — the silicon-carbide or silicon-nitride element grows brittle with every heating cycle and eventually cracks. The included wiring kit ensures a clean, terminated connection so you don't reuse a heat-fatigued harness. Typical failure symptoms are no ignition, the furnace locking out after several trial-for-ignition cycles, a visibly cracked or white-spotted element, or an igniter that no longer glows.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171306 (Igniter), 1188370 (Wiring Kit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003eIgniter element + wiring harness kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP RGS091LECA0AAA gas furnace and the equivalent Tempstar, Heil, Comfortmaker, and Arcoaire models that use igniter 1171306. Confirm the mounting bracket orientation against your existing igniter before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and electric power, then verify zero voltage at the igniter leads with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner-compartment door to reach the igniter and burner assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and harness routing before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter harness and remove the mounting screw; handle the old element by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter (never touch the element with bare fingers), connect the new wiring kit, and route the harness clear of hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the element glows and the burners light promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace ignition lockout \/ no heat on a call\u003c\/li\u003e\n\u003cli\u003eCracked, chipped, or white-spotted igniter element\u003c\/li\u003e\n\u003cli\u003eIgniter does not glow when energized\u003c\/li\u003e\n\u003cli\u003eRepeated trial-for-ignition cycles before the unit gives up\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027675464051,"sku":"1171306","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047623311731,"sku":"1171306-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1171306_f9ae3d30-3fe9-4091-9577-a0dfbae20c04.jpg?v=1782892017","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-for-rgs091leca0aaa-includes-wiring-kit-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}