{"product_id":"icp-hot-surface-igniter-electrode-for-rgs300htea0aaaa-oem-1179966-ships-today","title":"ICP Hot Surface Igniter Electrode for RGS300HTEA0AAAA — OEM 1179966 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM igniter electrode (part #1179966) is the hot surface ignitor that lights the gas burners in your ICP Tempstar\/Heil RGS300HTEA0AAAA gas furnace. On a heat call, line voltage energizes the igniter element, which glows white-hot and ignites the gas as it exits the burner ports. It is one of the most common furnace failure points because the brittle silicon-nitride\/carbide element degrades with every heating cycle and eventually cracks. Symptoms of a failed igniter include no heat, a furnace that cycles but never lights, or a unit that locks out after several failed ignition attempts. Replacing the igniter is routine seasonal maintenance on high-cycle systems.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBurner Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacement for the ICP Tempstar Heil RGS300HTEA0AAAA gas furnace and related RGS300 series models. Always confirm the mounting bracket and connector orientation against your original igniter before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect power; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace burner-compartment door.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the connector and remove the mounting screw; handle the old igniter by the ceramic base only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element, then reconnect the plug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power and confirm the igniter glows and the burners light on a heat call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNo heat despite the blower and inducer running\u003c\/li\u003e\n\u003cli\u003eFurnace locks out after repeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eIgniter shows cracks or no longer glows\u003c\/li\u003e\n\u003cli\u003eVisible breaks in the element or a no-continuity ohm reading\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027280576883,"sku":"1179966","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047619150195,"sku":"1179966-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_5c378d0f-dc68-4ff5-b0c2-93458bd14013.jpg?v=1782891865","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-electrode-for-rgs300htea0aaaa-oem-1179966-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}