{"product_id":"icp-hot-surface-igniter-electrode-for-rgs240ldaa0agaa-oem-ships-today","title":"ICP Hot Surface Igniter Electrode for RGS240LDAA0AGAA — OEM | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM igniter electrode (part number 1179966) provides the ignition source for the ICP\/Tempstar\/Heil model RGS240LDAA0AGAA furnace. On each heat call, the control board energizes the igniter, which heats to the temperature required to light the burner gas. Because the electrode is brittle and operates under repeated thermal cycling, it is one of the most common wear items in a gas furnace. A cracked or worn igniter is a leading cause of no-heat conditions where the inducer and gas valve operate normally but the burners never light.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1179966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eHot Surface Igniter Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM fit for the ICP\/Tempstar\/Heil RGS240LDAA0AGAA furnace. Compatible across ICP-family furnaces that share the same ignition electrode assembly. Confirm the mounting bracket orientation and connector style match your existing igniter before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off gas and disconnect furnace power, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the burner compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the igniter position and wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the igniter connector and unscrew the mounting bracket. Handle the old igniter by the base, never the ceramic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new igniter without touching the element with bare fingers, then reconnect the harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore gas and power, call for heat, and confirm the igniter glows and the burners light on the first attempt.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace runs the ignition sequence but burners never light (no-heat).\u003c\/li\u003e\n\u003cli\u003eVisible cracks, chips, or hot spots on the element.\u003c\/li\u003e\n\u003cli\u003eIgniter glows weakly or not at all during a heat call.\u003c\/li\u003e\n\u003cli\u003eRepeated lockouts after several failed ignition attempts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027302138227,"sku":"1179966","price":44.14,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047616266611,"sku":"1179966-GEN","price":33.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-igniter-silicon-carbide-1179966_13abb11c-ddce-470b-873c-4e069a07ce76.jpg?v=1782891732","url":"https:\/\/nationalhvacparts.com\/products\/icp-hot-surface-igniter-electrode-for-rgs240ldaa0agaa-oem-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}