{"product_id":"icp-furnace-control-board-kit-for-rgs214hdcb4baaa-integrated-ignition-control-ships-today","title":"ICP Furnace Control Board Kit for RGS214HDCB4BAAA — Integrated Ignition Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM control board kit (part \u003cstrong\u003e1183618\u003c\/strong\u003e) is the integrated furnace control (IFC) — the brain of your ICP \/ Heil \/ Tempstar RGS214HDCB4BAAA gas furnace. It manages the entire heating sequence: it reads the thermostat call, runs the inducer and pressure-switch proving, energizes the 120V hot surface igniter, opens the gas valve, monitors flame via the sensor, controls blower timing, and provides diagnostic fault codes through an onboard LED. When the board fails, the furnace may be completely dead, stuck in a single mode, blowing only cold air, or flashing error codes. The kit includes the replacement board and mounting hardware for a clean swap. Because the IFC ties the whole ignition and safety sequence together, a failed board is a no-heat emergency that this direct OEM replacement resolves.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIgnition sequencing, flame sensing, blower timing, LED diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS214HDCB4BAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit OEM kit for the ICP \/ Heil \/ Tempstar RGS214HDCB4BAAA gas furnace and related ICP-built furnaces specifying this control. Verify the board's connector layout matches your existing unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control\/blower compartment panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire harness and plug location on the old board before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug all connectors, remove the mounting screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board with the included hardware and reconnect each harness to its matching terminal per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for heat, and verify a full ignition sequence with no fault codes on the diagnostic LED.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace completely unresponsive to thermostat calls\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED flashing a board\/control fault code\u003c\/li\u003e\n\u003cli\u003eBlower or inducer runs continuously or not at all\u003c\/li\u003e\n\u003cli\u003eIntermittent operation or failure to complete the ignition sequence\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027316162931,"sku":"1183618","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047564624243,"sku":"1183618-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_7c89a38b-b3d2-4c72-b67f-ba28558bc9a3.jpg?v=1782889459","url":"https:\/\/nationalhvacparts.com\/products\/icp-furnace-control-board-kit-for-rgs214hdcb4baaa-integrated-ignition-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}