{"product_id":"icp-furnace-control-board-kit-for-rgs120sfcb0aaa-integrated-ignition-control-ships-today","title":"ICP Furnace Control Board Kit for RGS120SFCB0AAA | Integrated Ignition Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM control board kit (part number 1183618) is the integrated furnace ignition control for the ICP \/ Tempstar \/ Heil RGS120SFCB0AAA gas furnace. The board manages the complete heating sequence: it powers the inducer, proves the pressure switch, energizes the hot surface igniter, opens the gas valve, confirms flame via the sensor, and runs the blower on the correct heat and cool timings. It also provides the 24V control signals for thermostat calls and on-board diagnostics. When this board fails, the furnace loses its 'brain' and will not safely sequence a heat cycle. Common failure symptoms include no response to a thermostat call for heat, a furnace that locks out after one or two ignition attempts, a continuously running blower, or a diagnostic LED flashing a hard-fault code. Heat, line-voltage surges, condensation, and rodent damage are the usual culprits.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP \/ Tempstar \/ Heil RGS120SFCB0AAA gas furnace. The same control platform is shared across many ICP-family RGS and matched model variants. Always confirm the part number on your existing board before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control\/blower compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and connector on the board before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the wiring harnesses and connectors, then remove the mounting screws and lift the old board out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, transfer the jumper\/timing settings, and reconnect every harness exactly per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for heat, and confirm a full ignition sequence and correct blower operation; check the diagnostic LED for normal status.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo response from the furnace on a call for heat.\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or hard-fault diagnostic codes.\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously or fails to start.\u003c\/li\u003e\n\u003cli\u003eVisible burn marks, corrosion, or a blown trace\/fuse on the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027540328819,"sku":"1183618","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047554236787,"sku":"1183618-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_3d109f89-aa04-4e64-a73b-8a3ec6971428.jpg?v=1782889052","url":"https:\/\/nationalhvacparts.com\/products\/icp-furnace-control-board-kit-for-rgs120sfcb0aaa-integrated-ignition-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}