{"product_id":"icp-furnace-control-board-kit-for-rgs091lfcb0aaa-integrated-ignition-control-ships-today","title":"ICP Furnace Control Board Kit for RGS091LFCB0AAA — Integrated Ignition Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM control board kit (part #1183618) is the brain of your ICP, Heil, and Tempstar RGS091LFCB0AAA gas furnace. The integrated furnace control sequences the inducer, igniter, gas valve, and blower, monitors flame sense and limit\/pressure switches, and runs the diagnostic LED fault codes. When it fails you may see a dead furnace, blower that won't shut off, igniter that never energizes, or erratic flashing fault codes. Supplied as a complete kit with the correct board for a clean swap.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eIgnition, blower \u0026amp; safety sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eReplacement kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacement for the ICP\/Heil\/Tempstar RGS091LFCB0AAA gas furnace and matching chassis using the same control platform. Verify your full model and serial number prior to ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and connector on the existing board before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug all harnesses, release the board standoffs\/screws, and lift out the old control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board and reconnect each harness exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a full heat cycle, and confirm the diagnostic LED shows normal operation.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace completely dead with no diagnostic LED\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously or fails to start\u003c\/li\u003e\n\u003cli\u003eIgniter or gas valve never energizes on a heat call\u003c\/li\u003e\n\u003cli\u003eErratic or nonsensical LED fault codes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027674710387,"sku":"1183618","price":207.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047541391731,"sku":"1183618-GEN","price":159.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_60ce64c0-9085-482b-afba-2e7f434fed73.jpg?v=1782888686","url":"https:\/\/nationalhvacparts.com\/products\/icp-furnace-control-board-kit-for-rgs091lfcb0aaa-integrated-ignition-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}