{"product_id":"icp-furnace-control-board-kit-for-rgs090seca0aaa-integrated-ignition-control-ships-today","title":"ICP Furnace Control Board Kit for RGS090SECA0AAA — Integrated Ignition Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM integrated furnace control board kit (part #1183618) is the brain of the ICP\/Heil\/Tempstar RGS090SECA0AAA gas furnace. It sequences the entire heat cycle — energizing the inducer, proving the pressure switch, powering the hot surface igniter, opening the gas valve, monitoring flame via the sensor, and timing the blower on\/off delays. It also manages safety lockouts and flashes diagnostic fault codes via its onboard LED. When this board fails, symptoms range from a completely dead furnace to intermittent no-heat, blower running constantly, or repeated ignition lockouts. This kit ships with the correct board revision and mounting hardware for a direct replacement.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS090SECA0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOnboard LED fault codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect factory replacement for the ICP\/Heil\/Tempstar RGS090SECA0AAA furnace. Because furnace boards are revision-specific, confirm your existing board carries part number 1183618 (or its superseding kit) before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower compartment access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and connector on the existing board before removing anything; label any loose leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug all harness connectors and low-voltage leads, remove the mounting screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, then reconnect each harness and lead exactly per your photo. Verify there are no crossed connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a full heat cycle, and confirm correct sequencing and a clean diagnostic LED (no fault flashes).\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace completely dead with no diagnostic LED\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously or fails to start\u003c\/li\u003e\n\u003cli\u003eIntermittent no-heat or random ignition lockouts\u003c\/li\u003e\n\u003cli\u003eErratic or stuck fault codes that don't match field conditions\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027684016499,"sku":"1183618","price":246.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047539327347,"sku":"1183618-GEN","price":189.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_a2f8df89-513b-4469-96c0-367f86d63048.jpg?v=1782888625","url":"https:\/\/nationalhvacparts.com\/products\/icp-furnace-control-board-kit-for-rgs090seca0aaa-integrated-ignition-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}