{"product_id":"icp-furnace-control-board-for-wfar060b048b1-integrated-ignition-module-ships-today-1","title":"ICP Furnace Control Board for WFAR060B048B1 — Integrated Ignition Module | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM integrated furnace control board (part number 1184783) is the brain of the ICP\/Tempstar\/Heil WFAR060B048B1 gas furnace. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, firing the hot surface igniter, opening the gas valve, monitoring flame sense, and timing the blower on and off. It also enforces safety lockouts and reports fault codes via its diagnostic LED. When the board fails, the furnace may be completely unresponsive, stuck on the blower, short-cycle, or flash error codes that don't clear after checking sensors and switches. Replacing it restores correct, safe ignition and blower control.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1184783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOnboard fault-code LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil WFAR060B048B1 gas furnace and related ICP-family models using this integrated ignition control board. Confirm the board layout and connector positions against your original before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire harness and connector on the old board before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug all harnesses, remove the board mounting screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, transfer each connector to the matching terminal exactly per your photo, and set any required dip-switch\/jumper to match the original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a full heat cycle, and confirm correct ignition, blower timing, and a steady diagnostic LED.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace completely unresponsive to a call for heat\u003c\/li\u003e\n\u003cli\u003eBlower runs continuously or never starts\u003c\/li\u003e\n\u003cli\u003ePersistent fault codes that remain after sensors and switches check good\u003c\/li\u003e\n\u003cli\u003eVisible burn marks, corroded relays, or a no-light diagnostic LED\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027248300403,"sku":"1184783","price":214.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047529234803,"sku":"1184783-GEN","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1184783_11c8fc17-4228-4d6f-a6ae-79e04d3b91d5.jpg?v=1782888341","url":"https:\/\/nationalhvacparts.com\/products\/icp-furnace-control-board-for-wfar060b048b1-integrated-ignition-module-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}