{"product_id":"icp-fan-motor-for-waht184a1-ecm-x-13-1-3-hp-motor-control-module-ships-today","title":"ICP Fan Motor for WAHT184A1 — ECM X-13 1\/3 HP Motor Control Module | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ICP ECM X-13 motor control module (part #1185280) is the 1\/3 HP variable-speed blower motor used in the ICP\/Tempstar\/Heil WAHT184A1 air handler. The X-13 is a constant-torque ECM design that holds a programmed airflow against changing static pressure, giving quieter operation and lower energy use than a standard PSC motor. When this module fails the blower may run erratically, hum without spinning, run at a single fixed speed, or fail to start, leaving the system with no airflow even though the control board is calling for the blower.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eECM X-13 Motor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Technology\u003c\/td\u003e\n\u003ctd\u003eConstant-torque ECM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAir handler blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil WAHT184A1 fan coil air handler. Always confirm the part number on your existing motor module matches 1185280 before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the air handler service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the motor harness, control plug, and ground before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the ECM control connector, disconnect the line leads, and unbolt the motor module from the blower housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new module, reconnect the control plug and line leads exactly as photographed, and secure the ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the blower ramps to the programmed speed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower hums or buzzes but does not spin\u003c\/li\u003e\n\u003cli\u003eMotor runs at one fixed speed or surges up and down\u003c\/li\u003e\n\u003cli\u003eNo airflow despite a blower call from the control board\u003c\/li\u003e\n\u003cli\u003eIntermittent shutoffs or repeated motor faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021617316211,"sku":"1185280","price":245.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047521534323,"sku":"1185280-GEN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185280_4cc9e4db-00ee-4040-ac02-e63739643fbc.jpg?v=1782887976","url":"https:\/\/nationalhvacparts.com\/products\/icp-fan-motor-for-waht184a1-ecm-x-13-1-3-hp-motor-control-module-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}