{"product_id":"icp-fan-motor-for-wahl364b2-1-2-hp-ecm-x-13-blower-motor-control-ships-today","title":"ICP Fan Motor for WAHL364B2 — 1\/2 HP ECM X-13 Blower Motor Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM ICP ECM X-13 blower motor control module (part number 1185290), a 1\/2 HP variable-torque constant-airflow motor used as the indoor blower in ICP, Heil, and Tempstar air handlers and furnaces. The X-13 (also called Constant Torque) is an electronically commutated motor that holds a programmed torque across changing static pressure, delivering quieter operation and lower energy draw than a legacy PSC motor. When this motor fails you typically see no blower operation, intermittent or short-cycling airflow, a motor that hums but will not start, or a system that runs but never reaches setpoint because the indoor air handler is not moving air across the coil.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1185290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eECM X-13 Blower Motor \/ Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Class\u003c\/td\u003e\n\u003ctd\u003eElectronically Commutated (Constant Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndoor Blower \/ Air Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP \/ Heil \/ Tempstar WAHL364B2 air handler. This motor is shared across several ICP-family equipment lines that use the 1\/2 HP X-13 indoor blower platform. Always confirm the horsepower and the OEM part number stamped on your existing motor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the unit disconnect, then verify zero voltage at the motor leads with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wiring, the motor mount orientation, and the blower wheel position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the motor harness and control connector, loosen the blower wheel set screw, remove the motor mount band\/bolts, and slide the motor out of the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Transfer the blower wheel to the new motor shaft at the same depth, mount the motor, then reconnect the power and control harness exactly per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, start a call for cooling or heating, and confirm smooth blower ramp-up, correct airflow, and no unusual noise or vibration.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower will not start or only hums when energized\u003c\/li\u003e\n\u003cli\u003eIntermittent operation, surging, or short-cycling airflow\u003c\/li\u003e\n\u003cli\u003eWeak or no airflow at the registers with the system calling\u003c\/li\u003e\n\u003cli\u003eBurning smell, overheating, or visibly scorched windings\/control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021620527475,"sku":"1185290","price":245.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047521436019,"sku":"1185290-GEN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185290_16ad6b66-ef4a-4753-b4fa-9cb258f49179.jpg?v=1782887969","url":"https:\/\/nationalhvacparts.com\/products\/icp-fan-motor-for-wahl364b2-1-2-hp-ecm-x-13-blower-motor-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}