{"product_id":"icp-ecm-x-13-blower-motor-control-1-3-hp-for-waht304a2-ships-today","title":"ICP ECM X-13 Blower Motor Control 1\/3 HP for WAHT304A2 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ICP ECM X-13 motor control (part number 1185282) is the 1\/3 HP variable-efficiency blower motor used in the WAHT304A2 air handler. The X-13 is a constant-torque ECM (electronically commutated motor) that delivers higher efficiency and quieter, more consistent airflow than a standard PSC motor while responding to discrete tap selections from the control board. When an X-13 motor fails, you'll see no airflow, a motor that hums but won't spin, intermittent dropouts, or fault codes at the control board. The onboard module is the common failure point. Replacing it with the correct OEM 1\/3 HP X-13 control restores proper, efficient blower operation.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1185282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eECM X-13 Constant-Torque Blower Motor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Technology\u003c\/td\u003e\n\u003ctd\u003eECM X-13 (electronically commutated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAir handler \/ furnace blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP \/ Tempstar \/ Heil WAHT304A2 air handler and equivalent Comfortmaker fan coil units built around the X-13 ECM platform. Confirm horsepower (1\/3 HP), the X-13 motor technology, and the shaft\/mounting and connector configuration against your existing motor before installing — X-13 controls are tap-programmed and not interchangeable with PSC motors.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter before touching the motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the air handler service panel and slide out the blower assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the X-13 tap connections, line-voltage leads, and the blower wheel position on the shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Loosen the wheel set screw, pull the wheel, unplug the control connectors, and unbolt the old motor from the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new motor, reinstall the wheel at the documented depth, tighten the set screw on the shaft flat, and reconnect the tap and power leads exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the blower ramps up quietly and delivers strong airflow on each active tap.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo airflow, or a motor that hums but won't start\u003c\/li\u003e\n\u003cli\u003eBlower drops out intermittently or won't hold speed\u003c\/li\u003e\n\u003cli\u003eControl board throws a blower or motor fault code\u003c\/li\u003e\n\u003cli\u003eBurnt smell or visible damage at the motor's electronics module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021616726387,"sku":"1185282","price":284.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047517307251,"sku":"1185282-GEN","price":219.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-ecm-1185282.jpg?v=1782887743","url":"https:\/\/nationalhvacparts.com\/products\/icp-ecm-x-13-blower-motor-control-1-3-hp-for-waht304a2-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}