{"product_id":"icp-dual-run-capacitor-for-wama36004at2-35-5-mfd-440v-ships-today","title":"ICP Dual Run Capacitor for WAMA36004AT2 — 35+5 MFD 440V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM dual run capacitor (part 202300320025) is the factory replacement for the ICP\/Tempstar\/Heil WAMA36004AT2 3-ton condensing unit. A dual run capacitor provides the continuous phase-shift needed to run both the compressor (HERM terminal) and the outdoor condenser fan motor (FAN terminal) from a single component. Rated at 35+5 MFD and 440V, it stores and releases electrical energy to keep both motors turning efficiently. When a run capacitor weakens or fails, the compressor may hum but not start, the condenser fan may stall, the unit may trip the breaker, or you'll see hard starting and short cycling on hot days. This kit includes the OEM mounting strap (201270390202) so the capacitor seats securely in its bracket.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e202300320025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Hardware\u003c\/td\u003e\n\u003ctd\u003e201270390202 (Strap, Capacitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDual Run (round)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e35 + 5 MFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e440 VAC (compatible with 370V applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eHERM \/ FAN \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the direct OEM fit for the ICP\/Tempstar\/Heil WAMA36004AT2 condensing unit. The same dual run capacitor is shared across many 3-ton ICP-family outdoor units. Always confirm the MFD and voltage rating printed on your existing capacitor before ordering — a 440V capacitor safely replaces a 370V unit of the same MFD.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker. Verify zero voltage with a multimeter, then discharge the old capacitor across its terminals with an insulated screwdriver.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel to expose the electrical control area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wires on the HERM, FAN, and C terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Pull the spade connectors off, loosen the mounting strap, and lift out the old capacitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new capacitor in the bracket with the included strap, then reconnect each wire to its matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Replace the panel, restore power, and verify the compressor and condenser fan both start promptly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor hums or buzzes but won't start\u003c\/li\u003e\n\u003cli\u003eCondenser fan spins slowly or only after a manual push\u003c\/li\u003e\n\u003cli\u003eVisible bulging or leaking at the top of the capacitor can\u003c\/li\u003e\n\u003cli\u003eIntermittent cooling, short cycling, or tripped breakers in hot weather\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021614399859,"sku":"202300320025","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047513866611,"sku":"202300320025-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-capacitor-round-dual-202300320025_ce1f0718-7b25-4ec4-be95-02a8ecd73859.jpg?v=1782887601","url":"https:\/\/nationalhvacparts.com\/products\/icp-dual-run-capacitor-for-wama36004at2-35-5-mfd-440v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}