{"product_id":"icp-defrost-control-board-for-yj060ga2-oem-1069364-heat-pump-board-ships-today-1","title":"ICP Defrost Control Board for YJ060GA2 — OEM 1069364 Heat Pump Board | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the OEM defrost control board (part number 1069364) for the ICP \/ Tempstar \/ Heil YJ060GA2 heat pump. The defrost board governs the outdoor unit's heat-pump operation: it monitors outdoor coil temperature and accumulated run time, then periodically energizes the reversing valve and stops the outdoor fan to melt frost from the coil during heating. It also enforces compressor anti-short-cycle timing and safety lockouts. When this 24V board fails, the unit can no longer defrost — ice builds on the outdoor coil, heating output collapses, and the compressor may short-cycle or lock out. Typical symptoms include an iced-over outdoor unit, no heat in heat-pump mode, a reversing valve that will not shift, or a system stuck in perpetual defrost.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1069364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eYJ060GA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHeat Pump (outdoor unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFactory replacement defrost board for the ICP Tempstar Heil YJ060GA2 heat pump and equivalent ICP-family condensing units that originally shipped with part 1069364. The same board services multiple ICP badges including Tempstar, Heil, and Comfortmaker — confirm your existing board part number before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter at the board terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's control-access service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and connector at the board before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the low-voltage and line-voltage leads, release the board standoffs\/screws, and lift out the old defrost board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1069364 board on the same standoffs and reconnect every wire exactly as photographed, including the defrost thermostat sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, set the system to heat, and confirm the unit initiates and terminates a defrost cycle and that the reversing valve and outdoor fan respond.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil ices or frosts over and never clears\u003c\/li\u003e\n\u003cli\u003eNo heat in heat-pump mode or weak heating capacity\u003c\/li\u003e\n\u003cli\u003eUnit stuck in continuous defrost or never defrosts\u003c\/li\u003e\n\u003cli\u003eReversing valve fails to shift \/ no 24V output to the valve coil\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027188859251,"sku":"1069364","price":193.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047505281395,"sku":"1069364-GEN","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1069364_689738c7-fb62-4c74-be78-07089d14ab47.jpg?v=1782887250","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yj060ga2-oem-1069364-heat-pump-board-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}