{"product_id":"icp-defrost-control-board-for-yj024ga2-heat-pump-ships-today-1","title":"ICP Defrost Control Board for YJ024GA2 — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM defrost control board (part number 1069364) manages the defrost cycle on the ICP\/Tempstar\/Heil YJ024GA2 heat pump. Using inputs from the defrost thermostat\/sensor and an internal timer, the board decides when to reverse the system into defrost mode to melt frost off the outdoor coil, energizes the reversing valve and auxiliary heat, and controls the condenser fan during the cycle. A failed defrost board causes ice buildup on the outdoor coil, poor heating performance, or a unit that defrosts constantly or never at all.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1069364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Defrost Timing \u0026amp; Sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil YJ024GA2 heat pump and units sharing the same defrost board. Match the board's part number, connector layout, and timer pin settings to the original before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser control-box cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every connector and the timer\/jumper pin settings before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness connectors, note the defrost-timer pin position, and unscrew the old board from its standoffs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, set the defrost-timer pin to match the original, and reconnect each harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a heating cycle, and verify normal operation and (if accessible) a forced defrost.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy ice or frost accumulation on the outdoor coil in heating mode.\u003c\/li\u003e\n\u003cli\u003eUnit never enters defrost, or runs defrost far too often.\u003c\/li\u003e\n\u003cli\u003eWeak heating output or auxiliary heat that won't engage during defrost.\u003c\/li\u003e\n\u003cli\u003eNo response\/LED activity or visible burnt traces on the board.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027190661491,"sku":"1069364","price":188.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047504101747,"sku":"1069364-GEN","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1069364_0342e001-5278-403d-9479-3f7b775c11cd.jpg?v=1782887105","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yj024ga2-heat-pump-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}