{"product_id":"icp-defrost-control-board-for-yj024g-heat-pump-ships-today-1","title":"ICP Defrost Control Board for YJ024G — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM defrost control board (part number 34332101) manages the defrost cycle on ICP, Tempstar, and Heil YJ024G heat pumps. The board monitors coil temperature and run time, then commands the reversing valve and shuts off the outdoor fan to melt frost off the outdoor coil during cold-weather heating operation. It also coordinates the contactor and auxiliary heat staging. When this board fails, the heat pump may ice over completely, run defrost constantly, skip defrost entirely, or fail to energize the compressor. Typical symptoms include a heavily iced outdoor coil, no outdoor fan operation, the unit stuck in defrost (steam and warm-then-cold cycling), and no 24V output to the contactor. Because it carries control signals and relay loads, the board can fail from power surges, moisture intrusion, or burnt relay contacts.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e34332101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Defrost Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil YJ024G heat pump and shared-platform outdoor units using this defrost board. Match the part number and connector layout to your existing board before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire, plug, and the defrost sensor connection before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harnesses, release the board standoffs\/screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board on the standoffs and reconnect each harness per your photo, including the defrost thermostat\/sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a heat call, and verify normal operation and a forced defrost if your board supports a test pin.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and never defrosts\u003c\/li\u003e\n\u003cli\u003eUnit stuck running defrost repeatedly\u003c\/li\u003e\n\u003cli\u003eOutdoor fan won't run during heating\u003c\/li\u003e\n\u003cli\u003eNo 24V output to the contactor or reversing valve\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027190956403,"sku":"34332101","price":219.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047503970675,"sku":"34332101-GEN","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-34332101_8cbb2205-426b-404d-a0f0-6d2fb4a3b9c1.jpg?v=1782887085","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yj024g-heat-pump-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}