{"product_id":"icp-defrost-control-board-for-yg060gc2-34332101-oem-heat-pump-ships-today-1","title":"ICP Defrost Control Board for YG060GC2 — 34332101 OEM Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM defrost control board (part number 34332101) for the ICP\/Tempstar\/Heil YG060GC2 heat pump. The defrost board is the outdoor-unit logic controller: it monitors the defrost thermostat and the run-time clock, times the defrost cycle, energizes the reversing valve and auxiliary heat, and controls the condenser fan during a defrost. When it fails the heat pump can ice over and never defrost, defrost too often and waste energy, fail to switch the reversing valve, or stop running the outdoor fan. Boards commonly fail from power surges, moisture intrusion, and corroded relays, often showing scorched traces or stuck relays.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e34332101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eYG060GC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFactory replacement defrost control board for the ICP YG060GC2 and other Tempstar, Heil, and Comfortmaker heat pumps using this board. Match the part number and connector layout to your existing board, and note the defrost timing pin setting before swapping.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage at the board with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit service panel to expose the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every connector and the defrost timing jumper\/pin setting before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug each harness, release the standoffs or screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, set the defrost timing pin to match the original, and reconnect every harness per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a heating call, and verify normal operation and a correct timed defrost cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and the unit never defrosts.\u003c\/li\u003e\n\u003cli\u003eUnit defrosts far too frequently or at the wrong times.\u003c\/li\u003e\n\u003cli\u003eReversing valve or condenser fan won't energize on a defrost.\u003c\/li\u003e\n\u003cli\u003eVisible scorching, burnt relays, or corrosion on the board.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027192201587,"sku":"34332101","price":194.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047503708531,"sku":"34332101-GEN","price":149.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-34332101_4e324bb0-7191-4979-969e-016e3ee081ca.jpg?v=1782887048","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yg060gc2-34332101-oem-heat-pump-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}