{"product_id":"icp-defrost-control-board-for-yg060ga2-heat-pump-timer-ships-today-1","title":"ICP Defrost Control Board for YG060GA2 — Heat Pump Timer | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM defrost control board (part #1069364) for the ICP\/Heil\/Tempstar YG060GA2 heat pump. The defrost board governs the outdoor unit during heating mode: it watches the outdoor coil temperature sensor and the compressor's accumulated run time, then triggers a timed defrost cycle to clear frost and ice from the coil. A healthy board keeps the coil clear and the system efficient through cold weather. A failed board leaves the coil iced over, prevents the reversing valve from being commanded, or causes the compressor to run continuously with little heat output. The board runs on a 24V control circuit and coordinates the defrost relay, reversing valve, and auxiliary heat staging.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1069364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Outdoor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct-fit replacement for the ICP\/Heil\/Tempstar YG060GA2 heat pump and is shared across many same-vintage International Comfort Products heat pumps (Heil, Tempstar, Comfortmaker, Arcoaire, KeepRite). Confirm the part number on your current board before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control panel access cover on the outdoor unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal on the old board before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the low-voltage harness and sensor leads, remove the mounting screws\/standoffs, and lift out the failed board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new board on the standoffs, fasten it, and reconnect each wire to the matching terminal per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the unit heats, enters and exits a defrost cycle, and energizes the reversing valve.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil ices up and the unit never goes into defrost.\u003c\/li\u003e\n\u003cli\u003eHeat pump won't switch between heating and cooling.\u003c\/li\u003e\n\u003cli\u003eNo heat on cold days or constant compressor runtime.\u003c\/li\u003e\n\u003cli\u003eVisible scorching, burnt relays, or a board that won't power up.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027192627571,"sku":"1069364","price":155.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047503577459,"sku":"1069364-GEN","price":119.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1069364_c6b97ae5-f5eb-4a2f-bdeb-85f94f6ff326.jpg?v=1782887030","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yg060ga2-heat-pump-timer-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}