{"product_id":"icp-defrost-control-board-for-yg036ga2-heat-pump-ships-today-1","title":"ICP Defrost Control Board for YG036GA2 — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM defrost control board (part #1069364) is the brain of the ICP\/Tempstar\/Heil YG036GA2 heat pump's defrost cycle. The board monitors the defrost thermostat and run time, then commands the reversing valve, condenser fan, and auxiliary heat to clear frost from the outdoor coil during cold-weather operation. It also manages compressor timing and anti-short-cycle protection. When this board fails, the heat pump may ice over and lose heating capacity, run defrost cycles too often or never, fail to switch to backup heat, or leave the outdoor fan running when it shouldn't. Because the board carries both 24V control logic and switching relays, a failed board typically disables proper heating-mode operation entirely.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1069364\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDefrost timing, reversing valve \u0026amp; aux-heat control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect factory replacement for the ICP\/Tempstar\/Heil YG036GA2 heat pump and related ICP-family outdoor units that use this defrost control platform. Confirm the existing board's part number and connector layout before ordering, as defrost boards are model-specific.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's control\/electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every plug and wire location on the old board before unplugging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug all harness connectors, release the mounting standoffs\/screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board and reconnect each harness to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a heating cycle to confirm proper defrost and reversing-valve operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and the unit loses heating capacity\u003c\/li\u003e\n\u003cli\u003eDefrost cycle never runs, or runs far too frequently\u003c\/li\u003e\n\u003cli\u003eHeat pump won't energize backup\/auxiliary heat\u003c\/li\u003e\n\u003cli\u003eReversing valve or outdoor fan behaves erratically\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027193905523,"sku":"1069364","price":188.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047502889331,"sku":"1069364-GEN","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1069364_ea8b408e-61ac-40f4-bf0c-a5fc72567c14.jpg?v=1782886930","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yg036ga2-heat-pump-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}