{"product_id":"icp-defrost-control-board-for-yg018gc2-heat-pump-timer-board-ships-today-1","title":"ICP Defrost Control Board for YG018GC2 — Heat Pump Timer Board | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM defrost control board (part number 34332101) is the brain of the defrost cycle on the ICP \/ Heil \/ Tempstar YG018GC2 heat pump. Using the defrost thermostat input and a selectable timer interval, it decides when to interrupt heating, energize the reversing valve, stop the outdoor fan, and clear frost from the outdoor coil. A failed board leaves the coil iced over (killing heating capacity) or runs the unit through needless defrosts that blow cold air indoors. It also coordinates the contactor and reversing valve coil during the cycle, so a faulty board can mimic several other failures.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e34332101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost control \/ timer board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eYG018GC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDefrost timing, reversing valve \u0026amp; fan control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP YG018GC2 heat pump and the equivalent Heil, Tempstar, and Comfortmaker condensers built on the same platform. Match the part number and connector layout to your original board, and confirm any defrost-interval jumper settings during installation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser control-panel service cover to reach the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every plug, terminal, and jumper position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harness connectors, release the board standoffs or screws, and lift the old board out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, reconnect each harness per your photo, and set the defrost-interval jumper to match the original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, run a heat call, and confirm normal operation and a proper defrost cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and never defrosts.\u003c\/li\u003e\n\u003cli\u003eUnit defrosts too often or appears stuck in defrost.\u003c\/li\u003e\n\u003cli\u003eReversing valve or outdoor fan misbehaves during the defrost cycle.\u003c\/li\u003e\n\u003cli\u003eNo response, scorched components, or burnt smell at the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027195511155,"sku":"34332101","price":188.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047501152627,"sku":"34332101-GEN","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-34332101_95004d92-ba0d-4d2a-a186-0b54de2692e7.jpg?v=1782886850","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-yg018gc2-heat-pump-timer-board-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}