{"product_id":"icp-defrost-control-board-for-wch3614gkc210-heat-pump-ships-today-1","title":"ICP Defrost Control Board for WCH3614GKC210 — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ICP defrost control board (part number 1173636) is the brain of the WCH3614GKC210 heat pump's defrost cycle. It monitors the defrost thermostat and the timer interval, then commands the reversing valve and shuts off the outdoor fan to melt frost from the outdoor coil during heating operation. A failed board is a frequent cause of an outdoor coil icing solid, weak heat, a unit stuck in defrost, or the system failing to switch between heating and cooling. Replacing it restores correct, automatic defrost timing and protects the compressor.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1173636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDefrost timing \/ reversing valve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil WCH3614GKC210 heat pump. This board is shared across many comparable ICP-family heat pump condensers — verify the part number and connector layout against your existing board before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service\/control panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and connector position on the board before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the connectors, release the board standoffs\/screws, and lift the old board out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new board on its standoffs and reconnect each plug exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, initiate a defrost test, and confirm the reversing valve energizes and the fan cycles correctly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and never clears in heating mode\u003c\/li\u003e\n\u003cli\u003eUnit stuck in defrost or never enters defrost\u003c\/li\u003e\n\u003cli\u003eNo or weak heat output from the heat pump\u003c\/li\u003e\n\u003cli\u003eSystem won't switch properly between heating and cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027251446131,"sku":"1173636","price":214.5,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047492403571,"sku":"1173636-GEN","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1173636_1ba298d9-1206-4f26-9a5a-09cf716dc9d5.jpg?v=1782886513","url":"https:\/\/nationalhvacparts.com\/products\/icp-defrost-control-board-for-wch3614gkc210-heat-pump-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}