{"product_id":"icp-definite-purpose-contactor-for-rgs240htfa0aaaa-24v-coil-30a-40a-60a-ships-today","title":"ICP Definite Purpose Contactor for RGS240HTFA0AAAA — 24V Coil 30A\/40A\/60A | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis listing covers the genuine OEM definite-purpose contactors for the ICP\/Tempstar\/Heil RGS240HTFA0AAAA, available in three coil-matched ratings: 2-pole 30A (part 1171554), 3-pole 40A (part 1172449), and 3-pole 60A (part 1183142) — all with a 24V control coil. A contactor is the high-voltage switch that energizes the compressor and condenser fan whenever the thermostat closes a 24V call for cooling. The low-voltage coil pulls the contacts closed to pass line voltage to the load. Over time the contacts pit and burn, the coil weakens, or the contactor chatters and welds shut — causing no-cooling calls, a compressor that won't start, or a unit that won't shut off. Select the rating that matches your existing contactor.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171554, 1172449, 1183142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRatings\u003c\/td\u003e\n\u003ctd\u003e2P 30A \/ 3P 40A \/ 3P 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS240HTFA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacements for the ICP\/Tempstar\/Heil RGS240HTFA0AAAA. These Comfortmaker-family contactors are used across many RGS-series condensing units — match pole count and amp rating to your old contactor before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter on all line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser control-box service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires off the old contactor, unscrew it from the bracket, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly and the compressor\/fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing when energized\u003c\/li\u003e\n\u003cli\u003eCompressor and fan fail to start on a cooling call\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off because contacts stay closed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027304268147,"sku":"1171554","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047490142579,"sku":"1171554-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_e716f48c-cfdf-4eb1-ab79-783f3d882963.jpg?v=1782886362","url":"https:\/\/nationalhvacparts.com\/products\/icp-definite-purpose-contactor-for-rgs240htfa0aaaa-24v-coil-30a-40a-60a-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}