{"product_id":"icp-control-board-kit-for-rgs150hdcb0aaaa-oem-furnace-ignition-control-ships-today","title":"ICP Control Board Kit for RGS150HDCB0AAAA — OEM Furnace Ignition Control | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe 1183618 Control Board Kit is the integrated furnace control (IFC) for the ICP\/Tempstar\/Heil RGS150HDCB0AAAA gas furnace. This circuit board is the brain of the furnace — it sequences the ignition cycle, manages the inducer and blower relays, monitors safety limits and flame feedback, and runs onboard diagnostics. When the board fails the furnace typically will not start, will lock out on ignition faults, blows the onboard fuse, or runs the blower continuously. A flashing diagnostic LED with no heat call response is a classic symptom of a failed control board.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1183618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIntegrated Furnace Control Board Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Furnace Ignition Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150HDCB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eThis OEM control board is a direct fit for the ICP\/Tempstar\/Heil RGS150HDCB0AAAA furnace and is shared across related RGS150 series units that originally shipped with part 1183618. Always verify your existing board part number before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace blower-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections and connector positions before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug each harness connector and low-voltage wire, then remove the mounting screws and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board on the same standoffs and reconnect every connector exactly per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, initiate a heat call, and confirm the full ignition sequence and diagnostic LED show normal operation.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFurnace fails to start or does not respond to a thermostat heat call\u003c\/li\u003e\n\u003cli\u003eRepeated ignition lockouts or an error\/flash code on the board LED\u003c\/li\u003e\n\u003cli\u003eBlower or inducer runs continuously or not at all\u003c\/li\u003e\n\u003cli\u003eBlown onboard fuse or visible scorching\/burnt components on the board\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027432522099,"sku":"1183618","price":245.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047472316787,"sku":"1183618-GEN","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-furnace-1183618_89615fdc-bd88-47f1-be12-011e3b94da71.jpg?v=1782885657","url":"https:\/\/nationalhvacparts.com\/products\/icp-control-board-kit-for-rgs150hdcb0aaaa-oem-furnace-ignition-control-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}