{"product_id":"icp-contactor-set-30a-40a-60a-24v-coil-for-rhs243h0ea0aaaa-ships-today","title":"ICP Contactor Set 30A 40A 60A 24V Coil for RHS243H0EA0AAAA | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eOEM definite-purpose contactors for the ICP \/ Heil \/ Tempstar RHS243H0EA0AAAA heat pump, all using a 24VAC control coil. This listing covers the 2-pole 30A contactor (P\/N 1171554), the 3-pole 40A contactor (P\/N 1172449), and the 3-pole 60A contactor (P\/N 1183142). The contactor is the heavy-duty switch that closes line voltage to the compressor and outdoor fan motor whenever the thermostat energizes the 24V coil. Pitted, welded, or chattering contacts are one of the most common reasons a condenser won't start, hums without running, or short-cycles.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Pole 30A P\/N\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole 40A P\/N\u003c\/td\u003e\n\u003ctd\u003e1172449\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole 60A P\/N\u003c\/td\u003e\n\u003ctd\u003e1183142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A \/ 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole \u0026amp; 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompressor \u0026amp; Condenser Fan Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP-family RHS243H0EA0AAAA heat pump. Match your replacement to the pole count, amp rating, and 24V coil of the original contactor. The same definite-purpose footprint fits a wide range of Heil, Tempstar, and Comfortmaker condensing units.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e - Kill power at the disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e - Remove the condenser service panel to reach the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e - Photograph every line, load, and coil wire before removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e - Loosen the terminal screws, transfer one wire at a time, and unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e - Mount the new contactor, torque each lead to spec, and confirm the 24V coil leads land on the A1\/A2 terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e - Restore power and verify a crisp pull-in click and full contact closure on a cooling call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud humming or buzzing with no compressor start\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contact points\u003c\/li\u003e\n\u003cli\u003eChattering or rapid on\/off cycling of the outdoor unit\u003c\/li\u003e\n\u003cli\u003eCoil that won't pull the contacts in on a 24V signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027260817779,"sku":"1171554","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047461241203,"sku":"1171554-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_e1fc3871-133e-49f9-ba48-c65c5436e18d.jpg?v=1782885298","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-set-30a-40a-60a-24v-coil-for-rhs243h0ea0aaaa-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}