{"product_id":"icp-contactor-kit-for-rgs300hdaa0aaaa-2p-30a-3p-60a-24v-ships-today","title":"ICP Contactor Kit for RGS300HDAA0AAAA – 2P 30A \u0026 3P 60A 24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM contactor kit covers the definite-purpose contactors for the ICP \/ Tempstar \/ Heil RGS300HDAA0AAAA system: part 1171554 (2-pole, 30A, 24V coil) and part 1183142 (3-pole, 60A, 24V coil). A contactor uses a 24-volt control signal to pull in a set of heavy-duty contacts that switch line voltage to the compressor, fan motor, or electric-heat loads. Over time the contacts pit, arc, and weld, while the coil can burn open — causing no-start conditions, chattering, or a unit that won't shut off. Installing fresh OEM contactors restores clean, positive switching and protects the motors and heaters downstream.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171554 (2P), 1183142 (3P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30A (2P) \/ 60A (3P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacements for the ICP Tempstar Heil RGS300HDAA0AAAA and related models that use the 24V 30A 2-pole and 60A 3-pole contactors. Match the pole count, amp rating, and 24V coil to your existing component before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the electrical-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph all line, load, and coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer wires one at a time, unscrew the old contactor, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor and reconnect each terminal exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and confirm the contactor pulls in cleanly with no chatter on a call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering when energized\u003c\/li\u003e\n\u003cli\u003eUnit won't start or won't shut off\u003c\/li\u003e\n\u003cli\u003eOpen coil that fails to pull the contacts in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027282936179,"sku":"1171554","price":50.7,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047460520307,"sku":"1171554-GEN","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_be344c42-8ae7-4315-b56c-f257a760500b.jpg?v=1782885269","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-kit-for-rgs300hdaa0aaaa-2p-30a-3p-60a-24v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}