{"product_id":"icp-contactor-for-wjh442000ktp0a1-1-pole-30a-24v-coil-ships-today-1","title":"ICP Contactor for WJH442000KTP0A1 — 1-Pole 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM single-pole 30 amp definite-purpose contactor (part #1172472) with a 24V coil and integrated shunt for the ICP\/Tempstar\/Heil WJH442000KTP0A1 heat pump. The contactor is the high-voltage relay that the 24V thermostat circuit uses to switch line power to the compressor and condenser fan motor. On a call for cooling or heating the 24V coil pulls the contacts closed; when the contacts pit, weld, or the coil opens, the outdoor unit either won't start, chatters, or runs continuously. The built-in shunt protects against transient surges on the load side.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1172472 (CONTACTOR 1P 30A 24V W\/SHUNT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole Definite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eIntegrated Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit OEM replacement for the ICP family WJH442000KTP0A1 heat pump and shared platform units marketed under ICP, Tempstar, Heil, and Comfortmaker. Verify your original contactor is a 1-pole, 30A unit with a 24V coil before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and outdoor disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer the wires one at a time or label them, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line and load to the matching terminals and the 24V coil leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor\/fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or chatters but the compressor won't start\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts that stick closed\u003c\/li\u003e\n\u003cli\u003eCondenser fan and compressor run nonstop even with no cooling call\u003c\/li\u003e\n\u003cli\u003eBuzzing 24V coil or no continuity across the coil terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027229098355,"sku":"1172472","price":35.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047453442419,"sku":"1172472-GEN","price":26.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_b4516bbc-a1d1-41a0-8990-f0ec2963c8c5.jpg?v=1782884894","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-wjh442000ktp0a1-1-pole-30a-24v-coil-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}