{"product_id":"icp-contactor-for-wja342000k000a2-1-pole-30a-24v-coil-w-shunt-ships-today-1","title":"ICP Contactor for WJA342000K000A2 — 1-Pole 30A 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 1-pole definite purpose contactor (part number 1172472) is the primary switching relay for the outdoor condensing unit on your ICP WJA342000K000A2 system. Rated for 30 amps with a 24-volt control coil and an integrated shunt, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil is energized, the magnetic field pulls the contacts closed, completing the high-voltage line circuit to the compressor. A failed contactor is one of the most common reasons an air conditioner stops cooling. Typical failure symptoms include a humming or buzzing outdoor unit that will not start, pitted or welded contacts that keep the compressor running continuously, chattering, or no response at all when the thermostat calls for cool. Because the contacts arc every cycle, this is a wear part that should be replaced at the first sign of pitting.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1-Pole Definite Purpose Contactor w\/ Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWJA342000K000A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis contactor is a direct OEM replacement for the ICP WJA342000K000A2 condensing unit and shares the same platform across many Tempstar, Heil, and Comfortmaker units of the same tonnage. Always confirm the existing part number (1172472) and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel on the condensing unit to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line and 24V coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note the L1\/L2\/T1\/T2 and coil terminal positions, disconnect the wires, and unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, transfer each wire to the matching terminal per your photo, and confirm coil wires land on the 24V terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contacts pull in and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor will not start.\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eCompressor runs nonstop even when the thermostat is satisfied.\u003c\/li\u003e\n\u003cli\u003eChattering or clicking from the contactor during a cooling call.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027233522035,"sku":"1172472","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047452295539,"sku":"1172472-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_8206ba7d-aca9-491f-bd67-83a5a218d698.jpg?v=1782884854","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-wja342000k000a2-1-pole-30a-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}