{"product_id":"icp-contactor-for-wch3482gkr1-1-pole-30a-24v-coil-w-shunt-ships-today-1","title":"ICP Contactor for WCH3482GKR1 — 1-Pole 30A 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM single-pole definite purpose contactor (part #1172472) is the switching relay that energizes the compressor and condenser fan motor in your ICP\/Heil\/Tempstar WCH3482GKR1 heat pump. On a call from the thermostat, the 24V control circuit energizes the contactor coil, closing the contacts to send line voltage to the compressor. Rated for 30 amps with a 24-volt coil and an integrated shunt, it handles the high inrush current of compressor startup through thousands of cycles. Typical failure symptoms include a unit that hums but won't start, contacts that pit or weld shut so the compressor runs nonstop, chattering, or an audible buzz from the contactor. Burned contacts are among the most common causes of no-cool and no-heat service calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacement for the ICP\/Heil\/Tempstar WCH3482GKR1 heat pump condensing unit. Also fits many other ICP-family condensers and heat pumps using the same 1172472 contactor. Verify the part number on your existing contactor before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect box and breaker; verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in on a call for cooling and the compressor\/fan start normally.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit hums or buzzes but the compressor won't start.\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off (stuck closed).\u003c\/li\u003e\n\u003cli\u003eLoud chattering from the contactor when the system cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027252363635,"sku":"1172472","price":36.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047450198387,"sku":"1172472-GEN","price":28.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_b56c33ba-daf1-4037-90cd-22fe077b50c3.jpg?v=1782884780","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-wch3482gkr1-1-pole-30a-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}