{"product_id":"icp-contactor-for-wca3484gkg100-1-pole-30a-24v-w-shunt-ships-today","title":"ICP Contactor for WCA3484GKG100 — 1-Pole 30A 24V w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM 1-pole, 30-amp contactor with shunt (OEM part number 1172472) for the ICP\/Tempstar\/Heil WCA3484GKG100 air conditioning condensing unit. The contactor is the electrically operated switch that routes line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. A 24-volt control coil closes the single set of power contacts, while the built-in shunt maintains the unswitched leg of the circuit. After thousands of switching cycles the silver contacts pit and burn from arcing, creating chatter, hard starts, and voltage drop that strains the compressor. Replacing the contactor restores a clean electrical path and reliable cooling operation.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor with Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \u0026amp; Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned as a direct-fit replacement for the ICP\/Tempstar\/Heil WCA3484GKG100 condensing unit and other WCA-series systems that call for the 1172472 single-pole shunt contactor. Confirm the 30A rating, 1-pole layout, and 24V coil match your current part before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wires, including the shunt leg, before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil wires, then unscrew and lift out the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in and the unit starts.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHumming or chattering at the condenser when cooling begins.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contact points.\u003c\/li\u003e\n\u003cli\u003eCompressor and fan fail to start despite a cooling call.\u003c\/li\u003e\n\u003cli\u003eContacts stick closed and the unit will not shut off.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021606470003,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047447839091,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_00ff5a56-edb5-4c2d-9aac-1025aa847ccf.jpg?v=1782884691","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-wca3484gkg100-1-pole-30a-24v-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}