{"product_id":"icp-contactor-for-ryma75n001a-24v-coil-2p-20a-3p-30a-options-ships-today","title":"ICP Contactor for RYMA75N001A — 24V Coil, 2P 20A \/ 3P 30A Options | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM contactor for the ICP RYMA75N001A heat pump uses a 24-volt control coil to switch line power to the compressor and condenser fan. Available as a 2-pole 20A unit (part number 1054735) or a 3-pole 30A unit (part numbers 1070823 and 607339), the contactor closes its main contacts whenever the thermostat sends a 24V call, energizing the outdoor unit. Pitted, welded, or chattering contacts are the most common HVAC service failure: when the coil opens or the contacts burn, the compressor won't start or won't shut off. Typical symptoms include a humming contactor that won't pull in, a buzzing outdoor unit, contacts welded closed so the system runs nonstop, or visibly burnt and pitted contact surfaces.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1054735 (2P 20A), 1070823 \u0026amp; 607339 (3P 30A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Options\u003c\/td\u003e\n\u003ctd\u003e2-Pole \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp Rating\u003c\/td\u003e\n\u003ctd\u003e20A (2P) \/ 30A (3P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the contactor in the ICP \/ Tempstar \/ Heil RYMA75N001A and related ICP-family outdoor units. Select the pole count and amp rating that match your original contactor (2-pole 20A or 3-pole 30A) and confirm a 24V coil before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil connection before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label all leads, then unbolt the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, land the line and load conductors on the correct poles, and connect the 24V coil leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and send a cooling call; confirm the contactor pulls in cleanly and the compressor and condenser fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud hum or buzz from the contactor with no pull-in\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contact surfaces\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously because contacts won't open\u003c\/li\u003e\n\u003cli\u003eNo 24V at the coil or an open coil reading on the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027260555635,"sku":"1054735","price":36.4,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047445381491,"sku":"1054735-GEN","price":28.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1054735_c5f1c9d4-247e-44c1-984c-d9a5d11f0554.jpg?v=1782884572","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-ryma75n001a-24v-coil-2p-20a-3p-30a-options-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}