{"product_id":"icp-contactor-for-ryma10f001-30a-24v-coil-ships-today","title":"ICP Contactor for RYMA10F001 — 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM contactor is the factory-specified high-voltage relay for the \u003cstrong\u003eICP RYMA10F001\u003c\/strong\u003e heat pump. The contactor's 24V coil energizes when the thermostat calls for cooling or heating, pulling the contacts closed to send line voltage to the compressor and condenser fan motor. The RYMA10F001 platform uses several contactor variants depending on production date: a 1-pole 25A (PN 1050699), a 2-pole 20A (PN 1054735), and a 3-pole 30A (PN 1070823 \/ 607339) — all with a 24V control coil. When a contactor fails, the coil may not pull in (system won't start), the contacts can pit and weld shut (compressor runs continuously), or chattering causes hard-start damage.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1050699, 1054735, 1070823, 607339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-pole, 2-pole, 3-pole (by variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage\u003c\/td\u003e\n\u003ctd\u003e20A \/ 25A \/ 30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits ICP \/ Tempstar \/ Heil model \u003cstrong\u003eRYMA10F001\u003c\/strong\u003e heat pump condensing units. Confirm pole count, amperage, and coil voltage against your old contactor's label before ordering — the RYMA10F001 shipped with more than one contactor configuration over its production run.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker; verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note coil (24V) and line\/load lug positions, transfer one wire at a time, then unscrew the contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but compressor and fan won't start (coil failure).\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on inspection.\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering at the contactor when the system engages.\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running after the thermostat is satisfied (stuck contacts).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027260588403,"sku":"1050699","price":50.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047445184883,"sku":"1050699-GEN","price":38.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1050699_c88178ed-02ab-45e1-be17-0937e01d20f6.jpg?v=1782884558","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-ryma10f001-30a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}