{"product_id":"icp-contactor-for-rhs120l0bb0aaa-2-pole-30a-40a-24v-coil-ships-today","title":"ICP Contactor for RHS120L0BB0AAA — 2-Pole 30A\/40A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite-purpose contactor for the ICP\/Heil\/Tempstar RHS120L0BB0AAA heat pump. The contactor is the high-voltage relay that energizes the compressor and outdoor condenser fan motor whenever the thermostat calls for cooling or heating. When the 24V control signal reaches the coil, the magnetic core pulls the contacts closed and line voltage flows to the compressor. This package covers the two factory part numbers for this model — 1178074 (2-pole, 30A) and 1178211 (2-pole, 40A) — both with a 24-volt coil. A failing contactor is one of the most common no-cool service calls: pitted or welded contacts, a chattering coil, or a burned-out coil winding will leave the outdoor unit dead while the indoor blower still runs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRHS120L0BB0AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect-fit replacement for the ICP\/Heil\/Tempstar\/Comfortmaker RHS120L0BB0AAA heat pump and other RHS-series outdoor units that originally shipped with the 1178074 or 1178211 contactor. Always match the amperage and 24V coil rating to your original part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line- and low-voltage wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unbolt the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start but the indoor blower runs.\u003c\/li\u003e\n\u003cli\u003eLoud humming or buzzing from the contactor.\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eCompressor short-cycles or chatters on and off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021886374259,"sku":"1178074","price":38.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047444627827,"sku":"1178074-GEN","price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_0488c44e-d007-462f-9eb2-4aa4b4c09e77.jpg?v=1782884518","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rhs120l0bb0aaa-2-pole-30a-40a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}