{"product_id":"icp-contactor-for-rgs303hsea0aaaa-oem-2-pole-30a-3-pole-60a-24v-coil-ships-today","title":"ICP Contactor for RGS303HSEA0AAAA — OEM 2-Pole 30A \u0026 3-Pole 60A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThese OEM definite-purpose contactors switch the high-voltage power to the compressor and condenser fan on the ICP\/Heil\/Tempstar RGS303HSEA0AAAA. The kit covers two OEM options: part 1171554 (2-pole, 30A, 24V coil) and part 1183142 (3-pole, 60A, 24V coil). When the thermostat calls for cooling, the 24V coil pulls the contactor closed, sending line voltage to the compressor and fan motor. Contactors are high-cycle components whose contacts pit, arc, and weld over time. A failed contactor causes a unit that won't start, a compressor that runs continuously even after the call ends, or loud chattering at the contactor. Replacing with the correct OEM contactor restores clean, reliable switching and protects the compressor.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171554 (2P 30A), 1183142 (3P 60A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit replacement contactors for the ICP\/Heil\/Tempstar\/Comfortmaker RGS303HSEA0AAAA. Match the pole count and amp rating to your existing contactor: 2-pole 30A (1171554) or 3-pole 60A (1183142), both with a 24V coil.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect each lead, unfasten the contactor from its bracket, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line, load, and coil leads per your photo, matching pole positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor\/fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start on a cooling call.\u003c\/li\u003e\n\u003cli\u003eContactor chatters or buzzes loudly.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts that stick closed.\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running after the thermostat is satisfied.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027274973555,"sku":"1171554","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047444070771,"sku":"1171554-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_c201128a-31e6-45ed-9286-cf09eea72682.jpg?v=1782884474","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rgs303hsea0aaaa-oem-2-pole-30a-3-pole-60a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}