{"product_id":"icp-contactor-for-rgs244hrea0aaaa-24v-coil-30a-40a-60a-ships-today","title":"ICP Contactor for RGS244HREA0AAAA — 24V Coil 30A\/40A\/60A | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThese are the genuine OEM 24-volt contactors for the ICP \/ Tempstar \/ Heil RGS244HREA0AAAA gas\/electric package unit, available in 2-pole 30A (1171554), 3-pole 40A (1172449), and 3-pole 60A (1183142) configurations. The contactor is the high-amperage switch that energizes the compressor and condenser fan motor whenever the 24V coil receives a call for cooling from the control board. Its contacts make and break full line voltage thousands of times per season, so they eventually pit, burn, or weld. A failing contactor is one of the most common no-cool service calls: symptoms include a humming or buzzing contactor that won't pull in, a compressor that won't start, a unit that won't shut off because the contacts are welded closed, and visible arcing or burnt\/blackened contacts. Installing the correct OEM contactor restores reliable, safe switching at the factory amp and pole rating.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (2P 30A)\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (3P 40A)\u003c\/td\u003e\n\u003ctd\u003e1172449\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number (3P 60A)\u003c\/td\u003e\n\u003ctd\u003e1183142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A \/ 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole \/ 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRGS244HREA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit OEM contactors for the RGS244HREA0AAAA package unit and related ICP-family Tempstar\/Heil\/Comfortmaker units. Select the option that matches your existing contactor's pole count and amp rating; verify the 24V coil voltage before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter; discharge the run capacitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and remove the wires, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect line, load, and coil wires exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBuzzing or humming contactor that won't pull in on a cooling call.\u003c\/li\u003e\n\u003cli\u003eCompressor and condenser fan won't start.\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off — contacts welded closed.\u003c\/li\u003e\n\u003cli\u003ePitted, burnt, or blackened contacts and visible arcing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027283788147,"sku":"1171554-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047970980211,"sku":"1171554","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_97f8bd2f-361a-4be1-8ef8-98db230f05e3.jpg?v=1782884433","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rgs244hrea0aaaa-24v-coil-30a-40a-60a-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}