{"product_id":"icp-contactor-for-rgs214hraa0aaaa-2-pole-30a-24v-coil-ships-today","title":"ICP Contactor for RGS214HRAA0AAAA — 2-Pole 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM definite-purpose contactor for the ICP \/ Heil \/ Tempstar RGS214HRAA0AAAA gas furnace and its matched condensing unit. The contactor is the electrically operated switch that closes the high-voltage circuit to the compressor and condenser fan motor whenever the 24V control signal energizes its coil. This combo covers OEM part 1171554 (2-pole, 30A, 24V coil) and the interchangeable 1172449 (3-pole, 40A, 24V coil). When a contactor fails, the most common symptoms are a system that hums but will not start, pitted or welded contacts that keep the compressor running, or chattering from a weak coil. Replacing it is one of the most common HVAC service repairs.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171554, 1172449\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-pole (30A) \/ 3-pole (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eBuilt for the ICP\/Heil\/Tempstar RGS214HRAA0AAAA platform and shared family equipment from Comfortmaker and Day \u0026amp; Night using the same 24V-coil contactor. Verify pole count, amp rating, and coil voltage against the part you are removing before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the outdoor disconnect; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire positions before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each lead to match your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in on a call for cooling and drop out cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSystem hums but compressor and fan will not start\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering coil under load\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running after the thermostat is satisfied\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027315245427,"sku":"1171554","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047442792819,"sku":"1171554-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_d2d4ff93-ede7-41ae-b262-2cf6fd6cbb08.jpg?v=1782884369","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rgs214hraa0aaaa-2-pole-30a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}