{"product_id":"icp-contactor-for-rgs214hdhlbreta-30a-2-pole-40a-3-pole-24v-coil-ships-today","title":"ICP Contactor for RGS214HDHLBRETA — 30A 2-Pole \u0026 40A 3-Pole 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM contactor is the high-voltage switch that powers the compressor and condenser fan on the ICP (Tempstar \/ Heil) RGS214HDHLBRETA. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor. This listing covers the 2-pole 30A contactor (1171554) and the 3-pole 40A contactor (1172449), both with a 24V coil. Contactors are a common failure point: the contacts pit and burn over thousands of cycles, the coil can fail open, or insects\/debris can hold the contacts down. Symptoms include a buzzing or chattering unit, a compressor that won't start, or one that won't shut off. Specs: 24V coil, 30A (2-pole) or 40A (3-pole) contact rating.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554 (2P 30A), 1172449 (3P 40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A (2-pole) \/ 40A (3-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 or 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS214HDHLBRETA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP Tempstar\/Heil RGS214HDHLBRETA. Match the pole count and amp rating to your existing contactor — confirm whether your unit uses the 30A 2-pole or 40A 3-pole before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing-unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label them; unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in and the compressor starts on a cooling call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering at the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor won't start or won't shut off\u003c\/li\u003e\n\u003cli\u003eCoil reads open on a multimeter\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027315638643,"sku":"1171554","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047442727283,"sku":"1171554-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_1f597e9c-3ad8-429b-820e-c77f787f7e4e.jpg?v=1782884364","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rgs214hdhlbreta-30a-2-pole-40a-3-pole-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}