{"product_id":"icp-contactor-for-rgs210hraa0aaaa-2-pole-30a-3-pole-40a-24v-ships-today","title":"ICP Contactor for RGS210HRAA0AAAA — 2-Pole 30A \u0026 3-Pole 40A 24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM definite-purpose contactor for ICP, Tempstar, and Heil equipment, available as a 2-pole 30A (part 1171554) or 3-pole 40A (part 1172449) version, both with a 24-volt control coil. The contactor is the heavy-duty switch the thermostat uses to energize the compressor and condenser fan. When the 24V coil is energized by a cooling call, the contactor's contacts close and send line voltage to the outdoor unit; when the call ends, a spring opens the contacts. Because it cycles thousands of times per season, the contactor is a frequent wear item. Pitted, burned, or welded contacts cause hard starts, chattering, or a compressor that will not shut off, while a failed coil leaves the outdoor unit completely dead even though the indoor thermostat is calling for cooling.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1171554 (2P 30A), 1172449 (3P 40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole or 3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A (2P) \/ 40A (3P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP\/Tempstar\/Heil RGS210HRAA0AAAA and related ICP-family condensing units. Confirm whether your unit uses the 2-pole 30A or 3-pole 40A configuration and match the coil voltage (24V) before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, matching pole count and rating, and reconnect each wire per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a cooling call; confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit dead with 24V present at the coil\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing contactor during a cooling call\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contacts visible on the terminals\u003c\/li\u003e\n\u003cli\u003eCompressor that will not shut off due to stuck contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027329991027,"sku":"1171554","price":45.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047442334067,"sku":"1171554-GEN","price":34.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_cfd20771-4445-46e0-85fe-b6193793540f.jpg?v=1782884328","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-for-rgs210hraa0aaaa-2-pole-30a-3-pole-40a-24v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}