{"product_id":"icp-contactor-40a-2-pole-for-rhx036k0xa0aaa-24v-coil-ships-today","title":"ICP Contactor 40A 2-Pole for RHX036K0XA0AAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 40-amp definite-purpose contactor (part number 1176763) is the main switching relay for the ICP RHX036K0XA0AAA heat pump. Driven by the 24-volt control circuit, its electromagnetic coil closes two sets of heavy-duty silver-cadmium contacts to feed line-voltage power to the compressor and condenser fan motor on every call for heating or cooling. Rated 40 FLA per pole in a 2-pole configuration, it is built to absorb the high inrush of a scroll compressor start. When it fails you will typically see a unit that will not start, a loud hum or chatter at the outdoor section, contacts that are pitted or welded shut (causing the compressor to run nonstop), or visible arcing and burnt terminals. As one of the most-cycled components in the system, the contactor is a frequent and inexpensive wear-out item.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eA direct OEM replacement for the ICP RHX036K0XA0AAA heat pump and the family of Tempstar, Heil, and Comfortmaker outdoor units sharing this 40A platform. Confirm the printed part number and coil voltage on your existing contactor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser unit's service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer the line, load, and 24V coil leads one at a time from the old contactor, or unplug and unscrew it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to match your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in and the compressor and fan start on a call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor will not start.\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts visible on inspection.\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and will not shut off (stuck closed).\u003c\/li\u003e\n\u003cli\u003eIntermittent cooling caused by chattering or dropped contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021835813235,"sku":"1176763","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047441940851,"sku":"1176763-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_f93a5a60-71e8-48c5-b5b0-8f05d69927c5.jpg?v=1782884295","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-40a-2-pole-for-rhx036k0xa0aaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}