{"product_id":"icp-contactor-2-pole-30a-24v-for-rgs300lraa0aaaa-definite-purpose-ships-today","title":"ICP Contactor 2-Pole 30A 24V for RGS300LRAA0AAAA — Definite Purpose | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite-purpose contactor (part number 1171554) rated for 30 amps with a 24-volt coil, built for the ICP \/ Heil \/ Tempstar RGS300LRAA0AAAA. The contactor is the heavy-duty relay that switches line voltage to the compressor and condenser fan motor on a call for cooling. The 24V coil is energized by the control circuit, pulling the contacts closed to send power to the high-voltage loads. When a contactor wears out, the contacts pit, weld, or chatter — causing a unit that won't start, hums without engaging, or short-cycles. Installing the correct 2-pole 30A OEM contactor restores reliable switching and protects the motor and compressor.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct-fit replacement for the ICP \/ Heil \/ Tempstar RGS300LRAA0AAAA. As a definite-purpose contactor, it also serves as a common replacement across many residential condensing units and air conditioners using a 2-pole, 30A, 24V coil configuration. Always confirm your existing contactor's pole count, amp rating, and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the unit's service disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo, ensuring tight terminal connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in cleanly on a cooling call with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit hums but the compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted contacts.\u003c\/li\u003e\n\u003cli\u003eContactor chatters or buzzes instead of pulling in firmly.\u003c\/li\u003e\n\u003cli\u003eSystem short-cycles or fails to respond to the thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027279298931,"sku":"1171554","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047441678707,"sku":"1171554-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_5737f8ae-e3eb-433b-9365-f867d87e2315.jpg?v=1782884270","url":"https:\/\/nationalhvacparts.com\/products\/icp-contactor-2-pole-30a-24v-for-rgs300lraa0aaaa-definite-purpose-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}