{"product_id":"icp-condenser-fan-motor-for-wpg4604130rkb1-1-5-hp-810-rpm-ships-today-1","title":"ICP Condenser Fan Motor for WPG4604130RKB1 — 1\/5 HP 810 RPM | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM condenser fan motor (part number 1186359) is the outdoor fan motor for the ICP\/Tempstar\/Heil WPG4604130RKB1 packaged unit. Rated at 1\/5 HP and 810 RPM, it drives the condenser fan blade that pulls air across the outdoor coil to reject heat during cooling. Designed for 208\/230V operation, it is the direct factory replacement that maintains correct airflow, amp draw, and bearing life. A failing condenser fan motor is one of the most common causes of high head pressure, compressor overheating, and complete loss of cooling on warm days. Common symptoms include a fan that hums but will not spin, a blade that spins freely by hand but stalls under power, hot or noisy bearings, and a unit that trips on high-pressure or thermal overload.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1186359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCondenser Fan Motor (CND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e810 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eOutdoor condenser fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory-spec condenser fan motor for the ICP\/Tempstar\/Heil WPG4604130RKB1 packaged unit. The same motor is shared across many WPG-series gas\/electric package units of the same tonnage and electrical rating. Always confirm HP, RPM, voltage, rotation, and shaft size against your existing motor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the unit and main panel, then verify zero voltage at the motor leads with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the top fan deck or service panel to reach the motor and fan blade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photo all wire connections and the blade-to-motor position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Loosen the blade set screw, slide off the fan blade, unbolt the motor from the bracket, and disconnect the leads and run capacitor wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new motor, transfer the blade at the same depth, reconnect leads to the capacitor per your photo, and confirm correct rotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, verify smooth start and proper airflow, and check amp draw against the nameplate.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor fan hums but does not spin, or only starts with a hand push.\u003c\/li\u003e\n\u003cli\u003eLoud grinding, squealing, or rattling bearings.\u003c\/li\u003e\n\u003cli\u003eUnit trips on high-pressure or thermal overload during cooling.\u003c\/li\u003e\n\u003cli\u003eMotor body is overheating, smells burnt, or amp draw exceeds the nameplate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027205538163,"sku":"1186359","price":168.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047440007539,"sku":"1186359-GEN","price":129.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-condenser-fan-motor-1186359_db0934be-a3e5-4aa1-a438-9bb9c815d73a.jpg?v=1782884160","url":"https:\/\/nationalhvacparts.com\/products\/icp-condenser-fan-motor-for-wpg4604130rkb1-1-5-hp-810-rpm-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}