{"product_id":"icp-blower-motor-for-wfmr070a036b2-1-3-hp-3-speed-furnace-blower-ships-today","title":"ICP Blower Motor for WFMR070A036B2 — 1\/3 HP 3-Speed Furnace Blower | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the OEM 1\/3 HP, 3-speed blower motor (OEM 1184882) for the ICP \/ Tempstar \/ Heil WFMR070A036B2 gas furnace. The blower motor drives the indoor squirrel-cage wheel that pushes conditioned air through the supply ductwork on both heating and cooling cycles. The three speed taps let the installer match airflow to the heating and cooling stages. A failing blower motor is a frequent cause of weak airflow, overheating limit trips in heat mode, and frozen evaporator coils in cooling mode. Bad bearings produce a grinding or squealing noise, while a shorted or open winding will trip the breaker or leave the blower dead while the rest of the furnace sequences normally.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1184882\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDirect-Drive Furnace Blower Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeeds\u003c\/td\u003e\n\u003ctd\u003e3-Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWFMR070A036B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eBuilt as a direct OEM fit for the ICP WFMR070A036B2 furnace and its equivalents under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Verify horsepower, speed count, shaft size, and rotation against your existing motor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the switch and breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the blower-compartment panel and slide out the blower assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every speed-tap and capacitor wire and note the blower-wheel position on the shaft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Loosen the wheel set screw, pull the wheel, unbolt the old motor from the mount, and transfer the mounting band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Bolt the new motor in, reset the wheel to the original depth, torque the set screw on the shaft flat, and reconnect each speed lead per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm smooth, quiet rotation and correct airflow on heating and cooling speeds.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWeak or no airflow at the supply registers.\u003c\/li\u003e\n\u003cli\u003eGrinding, squealing, or humming from the blower section.\u003c\/li\u003e\n\u003cli\u003eFurnace trips the high-limit on heat or freezes the coil on cool.\u003c\/li\u003e\n\u003cli\u003eMotor runs hot, smells of burnt insulation, or trips the breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021567410547,"sku":"1184882","price":220.94,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047435518323,"sku":"1184882-GEN","price":169.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-blower-motor-psc-1184882_10a92032-a3fc-4004-b3fd-1ef19654b0df.jpg?v=1782883786","url":"https:\/\/nationalhvacparts.com\/products\/icp-blower-motor-for-wfmr070a036b2-1-3-hp-3-speed-furnace-blower-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}