{"product_id":"icp-40va-transformer-for-wfar100c048b2-120v-to-24v-ships-today","title":"ICP 40VA Transformer for WFAR100C048B2 — 120V to 24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM control transformer (part #1177217, TRANSFORMER 40VA 120-24V) supplies the 24-volt control power for the ICP\/Heil\/Tempstar WFAR100C048B2. It steps the 120V line voltage down to the 24VAC that operates the thermostat, control board, gas valve, relays, and contactor circuits. Rated at 40VA, it provides enough capacity to drive the full low-voltage control load. When a transformer fails, the entire control side of the system goes dead even though line voltage is present — the thermostat goes blank, nothing energizes, and the system will not start. Transformers commonly fail from a shorted control wire, a seized component drawing excess current, or simple age-related winding breakdown. This OEM unit matches the factory primary\/secondary voltages and mounting so it drops straight in.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1177217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eStep-Down Control Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDesigned for the ICP\/Heil\/Tempstar WFAR100C048B2 and matching WFAR-series units that use a 40VA 120-to-24V control transformer. Verify your primary is 120V before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the primary and secondary leads before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unfasten the transformer mounting and disconnect the wire leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new transformer, land the 120V primary and 24V secondary leads per your photo, and check for any shorted control wiring first.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm 24VAC at the secondary and a live thermostat.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThermostat display is blank with line power present\u003c\/li\u003e\n\u003cli\u003eNo 24V output measured at the secondary\u003c\/li\u003e\n\u003cli\u003eSystem will not energize any control component\u003c\/li\u003e\n\u003cli\u003eTransformer is hot, buzzing, or smells burnt\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021591560563,"sku":"1177217-GEN","price":28.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047955153267,"sku":"1177217","price":37.63,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1177217_a678d0e0-b3ad-410c-aea1-f730b5b725bf.jpg?v=1782882675","url":"https:\/\/nationalhvacparts.com\/products\/icp-40va-transformer-for-wfar100c048b2-120v-to-24v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}