{"product_id":"icp-40a-contactor-for-wch460gka210-24v-coil-condenser-ships-today","title":"ICP 40A Contactor for WCH460GKA210 — 24V Coil Condenser | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM 40-amp contactor (part #1176763) is the main switching relay for the ICP\/Tempstar\/Heil WCH460GKA210 condensing unit. A contactor is an electrically operated switch: when the thermostat sends a 24V signal, the coil pulls the contacts closed and sends line voltage to the compressor and condenser fan motor. Because it cycles every time the system runs, the contacts pit, burn, and weld over time — and the coil can fail open. A bad contactor is one of the most common reasons an outdoor unit won't start or won't shut off. At 40A this contactor carries the full load of the compressor plus fan with margin to spare.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWCH460GKA210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil WCH460GKA210 and shared ICP-family condensing units. Confirm the amp rating and 24V coil voltage stamped on your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label each, unscrew the mounting, and remove the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect line, load, and coil leads exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, send a cooling call, and confirm the contacts pull in and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start despite a cooling call\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off (contacts stuck closed)\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering contactor \/ failed 24V coil\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027250463091,"sku":"1176763-GEN","price":36.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047950303603,"sku":"1176763","price":46.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_950c378d-3f7b-4e03-bf1e-0c4d2e9af27f.jpg?v=1782882291","url":"https:\/\/nationalhvacparts.com\/products\/icp-40a-contactor-for-wch460gka210-24v-coil-condenser-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}