{"product_id":"icp-40a-contactor-for-rgx060kexa0aaa-2-pole-24v-coil-ships-today","title":"ICP 40A Contactor for RGX060KEXA0AAA — 2-Pole 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM 40-amp definite purpose contactor (part #1176763) for the ICP\/Heil\/Tempstar RGX060KEXA0AAA furnace. A contactor is an electrically operated switch that uses a low-voltage 24V control signal from the thermostat or control board to close high-current line-voltage contacts, energizing the unit's load. When the contactor fails, the system may not start, may chatter or hum, or may run continuously because the contacts have welded shut. Pitted, burned, or carbon-fouled contacts are the most common failure point on any HVAC system. This 2-pole, 40A contactor restores reliable, positive switching.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct OEM replacement for the ICP\/Heil\/Tempstar RGX060KEXA0AAA. The 40A, 2-pole, 24V-coil configuration is also common across many ICP-family gas furnaces and condensing units that use the same switching specification — always confirm against your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching any wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire positions on the contactor before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly as shown in your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for operation, and confirm the contactor pulls in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit will not start or starts intermittently\u003c\/li\u003e\n\u003cli\u003eLoud humming, buzzing, or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contacts\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously because contacts are welded closed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027268092275,"sku":"1176763-GEN","price":34.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047949353331,"sku":"1176763","price":45.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_9e2dc952-d45c-4a81-a643-7715be088ee9.jpg?v=1782882230","url":"https:\/\/nationalhvacparts.com\/products\/icp-40a-contactor-for-rgx060kexa0aaa-2-pole-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}