{"product_id":"icp-3-pole-30a-contactor-for-ryma75f001-24v-coil-ships-today","title":"ICP 3-Pole 30A Contactor for RYMA75F001 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM definite-purpose contactor for the ICP (International Comfort Products) RYMA75F001 heat pump. The contactor is the high-voltage relay that switches line power to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heating. This assembly covers the 3-pole, 30 amp, 24V-coil contactor (OEM 1070823 \/ 607339) as well as the 2-pole, 20 amp, 24V-coil variant (OEM 1054735) used across this model line. When the 24V coil is energized by the thermostat, the contactor pulls in and closes its line-voltage contacts; when the call ends, it drops out. Because it cycles every time the system runs, the contacts pit, burn, and weld over years of service — the single most common reason an outdoor unit will hum but fail to start, chatter, or refuse to shut off.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1070823, 607339 (3P 30A), 1054735 (2P 20A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3-Pole (also 2-Pole variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amp (20 Amp on 2-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP RYMA75F001 heat pump and its sister Heil, Tempstar, and Comfortmaker condensing units. Confirm pole count and amp rating against the contactor currently installed in your unit before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-panel service cover on the side of the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and pull the line, load, and 24V coil leads, then unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, transfer each wire to the matching terminal per your photo, and confirm the coil leads land on the 24V terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, place a cooling\/heating call, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contacts.\u003c\/li\u003e\n\u003cli\u003eContactor chatters or pulls in and drops out rapidly.\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously and won't shut off because the contacts have welded closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021834535283,"sku":"1054735","price":44.2,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047364116851,"sku":"1054735-GEN","price":34.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1054735.jpg?v=1782882148","url":"https:\/\/nationalhvacparts.com\/products\/icp-3-pole-30a-contactor-for-ryma75f001-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}