{"product_id":"icp-2-pole-contactor-for-rhs090l0ba0aaaa-30a-40a-24v-coil-ships-today","title":"ICP 2-Pole Contactor for RHS090L0BA0AAAA — 30A\/40A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM 2-pole definite purpose contactor for the ICP (International Comfort Products) RHS090L0BA0AAAA heat pump system, covering OEM part numbers 1178074 (2-pole, 30A) and 1178211 (2-pole, 40A). The contactor is the high-voltage switch that energizes your compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump heating. A low-voltage 24V signal from the control board pulls in the coil, closing the line-voltage contacts. Over thousands of cycles the contacts pit, burn, and weld, and the coil weakens — leading to compressors that won't start, chattering relays, or a unit that runs continuously and won't shut off. Replacing a worn contactor is one of the most common and cost-effective HVAC repairs.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Voltage\u003c\/td\u003e\n\u003ctd\u003eup to 600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP RHS090L0BA0AAAA heat pump and shared across many ICP-family condensing units sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Verify your existing contactor's pole count, amp rating, and 24V coil before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the contactor terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note line, load, and 24V coil leads, then transfer wires one at a time to the new contactor, or unscrew the old unit from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in on a cooling call and that the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompressor or condenser fan won't start, or only starts when you tap the contactor.\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor.\u003c\/li\u003e\n\u003cli\u003eVisibly burnt, pitted, or melted contacts.\u003c\/li\u003e\n\u003cli\u003eUnit runs nonstop and won't shut off (welded contacts).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021888274803,"sku":"1178074-GEN","price":26.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047942406515,"sku":"1178074","price":35.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_a4905aeb-031d-4674-b90d-1d087c200d95.jpg?v=1782881740","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-contactor-for-rhs090l0ba0aaaa-30a-40a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}