{"product_id":"icp-2-pole-contactor-for-rgs150staa0agaa-30a-40a-24v-coil-ships-today","title":"ICP 2-Pole Contactor for RGS150STAA0AGAA – 30A \u0026 40A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eGenuine OEM 2-pole definite-purpose contactors for the ICP \/ Tempstar \/ Heil RGS150STAA0AGAA. This listing covers the unit's contactor options: a 2-pole 30A contactor (OEM 1178074) and a 2-pole 40A contactor (OEM 1178211), both with a 24V control coil. A contactor is the electrically operated switch that closes the line-voltage circuit when the 24V thermostat\/control signal energizes the coil, sending power to the compressor and condenser fan. Contactors are high-cycle wear items: the coil can burn open and the silver contacts pit, weld, or corrode over time. A failed contactor is one of the most common causes of a unit that won't start, chatters, or runs continuously.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A (FLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eBuilt for the ICP RGS150STAA0AGAA and used across many ICP-family Tempstar, Heil, and Comfortmaker units. Match the amp rating (30A or 40A) and the 24V coil to the part called out in your unit's wiring diagram before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the disconnect and breaker, then confirm zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the electrical control panel cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph all line, load, and 24V coil wiring before removing any leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer wires one at a time or label each lead, then unbolt the old contactor from the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor, reconnect every wire to the matching terminal per your photo, and torque to spec.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power, call for cooling\/heating, and confirm the contactor pulls in cleanly and the unit energizes.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit won't start or hums but won't pull in.\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing at the contactor.\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eCompressor\/fan runs continuously even with no call.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027354042739,"sku":"1178074-GEN","price":34.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047941226867,"sku":"1178074","price":45.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_4763f1fa-6c17-4daf-ba8f-bf5435e1fcc0.jpg?v=1782881668","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-contactor-for-rgs150staa0agaa-30a-40a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}