{"product_id":"icp-2-pole-contactor-for-rgs091hfbb0aaaa-30a-40a-24v-coil-ships-today","title":"ICP 2-Pole Contactor for RGS091HFBB0AAAA — 30A\/40A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite purpose contactor (part numbers 1178074 and 1178211) is the switching relay that energizes the compressor and condenser fan in your ICP \/ Tempstar \/ Heil RGS091HFBB0AAAA furnace and matched cooling system. When the 24-volt control signal from the thermostat hits the coil, the magnetic core pulls the contacts closed and routes line voltage to the load. Rated at 30 amps (1178074) and 40 amps (1178211) across 2 poles with a 24V coil, it handles the inrush of a starting compressor without welding. Failure shows up as a system that hums but won't start, pitted or burned contacts, a buzzing or chattering coil, or a compressor that fails to engage on a call for cooling.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS091HFBB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP \/ Tempstar \/ Heil RGS091HFBB0AAAA and other matched ICP-family condensing units and furnaces that call for a 2-pole, 24V-coil contactor. Confirm pole count, amp rating, and coil voltage against the contactor currently installed before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and detach each wire, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in and the compressor starts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBurned, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor coil\u003c\/li\u003e\n\u003cli\u003eCompressor hums but will not start\u003c\/li\u003e\n\u003cli\u003eNo 24V pull-in when the thermostat calls for cooling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027678970227,"sku":"1178074-GEN","price":34.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047937065331,"sku":"1178074","price":44.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_84401a5a-3c0d-4209-b79d-2161b88e198f.jpg?v=1782881494","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-contactor-for-rgs091hfbb0aaaa-30a-40a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}