{"product_id":"icp-2-pole-40a-contactor-for-wca3602gkr2-oem-1176763-ships-today-1","title":"ICP 2-Pole 40A Contactor for WCA3602GKR2 — OEM 1176763 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM 40-amp definite purpose contactor (part number 1176763) for the ICP\/Heil\/Tempstar WCA3602GKR2 condensing unit. The contactor is the electrically operated switch that delivers high-voltage power to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling. This 2-pole unit is rated 40 amps per pole with a 24-volt coil. When it fails, the outdoor unit won't start, buzzes without engaging, or sticks closed and runs continuously. Pitted, burned, or welded contacts are the most common cause of a no-cool condition.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWCA3602GKR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as the exact OEM replacement for the ICP\/Tempstar\/Heil WCA3602GKR2 air conditioner condensing unit. This 40A 2-pole 24V contactor is a common service part across many ICP-family WCA-series outdoor units that use the same control voltage and amp rating. Confirm your existing contactor's poles, amp rating, and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel to expose the electrical compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo (24V coil terminals, line\/load on the poles).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the contactor pulls in on a cooling call and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan don't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contactor.\u003c\/li\u003e\n\u003cli\u003eContacts welded shut, causing the unit to run nonstop.\u003c\/li\u003e\n\u003cli\u003eChattering contactor or intermittent cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027256361331,"sku":"1176763-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047932838259,"sku":"1176763","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_5b5dcb47-5772-42c4-a694-d4c03a247a71.jpg?v=1782881318","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-40a-contactor-for-wca3602gkr2-oem-1176763-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}