{"product_id":"icp-2-pole-30a-contactor-for-rhs150s0ea0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHS150S0EA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM definite purpose contactor energizes the compressor and condenser fan motor in your ICP RHS150S0EA0AAAA heat pump. When the thermostat calls, the 24V control circuit pulls the contactor coil in, closing the 2-pole, 30-amp contacts and feeding line voltage to the outdoor unit. Rated 30A per pole with a 24-volt coil, it withstands the high inrush of compressor start-up across thousands of cycles. The contacts eventually pit, burn, and arc-weld, and debris or insects can wedge under them. Typical failure signs include a buzzing or chattering outdoor unit, a compressor that hums but won't start, a condenser fan that runs continuously, or a completely dead outdoor unit while the indoor blower still runs. This is one of the most common and cost-effective HVAC repairs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM fit for the ICP \/ Heil \/ Tempstar \/ Comfortmaker RHS150S0EA0AAAA heat pump condensing unit. ICP shares this 2-pole 30A 24V contactor platform across many RHS-series single-stage outdoor units, making it a frequent replacement on comparable condensers. Verify your existing contactor is 2-pole with a 24V coil before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note line (L1\/L2), load (T1\/T2), and 24V coil wire positions, then transfer wires one at a time or unbolt the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eCompressor and fan won't start despite a thermostat call\u003c\/li\u003e\n\u003cli\u003eVisibly burnt, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCondenser fan runs nonstop or unit stays energized after the call ends\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021856358771,"sku":"1178074-GEN","price":29.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047930315123,"sku":"1178074","price":37.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_0faeb0d6-7e82-49f8-bde1-2f8707ff4341.jpg?v=1782881160","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhs150s0ea0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}